Technical Specification ICEU225FA Condensing Unit Air Cooled Ice production per 24 hrs at 70 Deg Air / Lbs (Kgs) 211 (96) Ice production per 24 hrs at 90 Deg Air / Lbs (Kgs) 143 (65) Water used gals per 100 lbs of ice 90 deg air 32.7 (124) Kilowatts used per 100 lbs of ice 90 deg air 8.8 Btuh 3774 Voltage 220-240V, 50Hz,1phase No. of wires 3 Min Circuit current 4.9 Amps Max. Fuse Size 15 Width x Depth x Height 24" x 24" x 39" (60.96 cm x 60.96 cm x 99.06 cm) Weight 175 lb (79.3800 kg) Power Output 230 Watts Air Temp ° F (° C) Water Temp. °F (°C) 80(27°) 70°(21°) 50°(10°) 90 (32) 133 (60) 143 (65) 170 (77) 80 (27) 161 (73) 173 (79) 191(87) 70 (21) 178 (81) 192 (87) 211 (96)
Technical Specification
ICEU225FA
Condensing Unit
Air Cooled
Ice production per 24 hrs at 70 Deg Air / Lbs (Kgs)
211 (96)
Ice production per 24 hrs at 90 Deg Air / Lbs (Kgs)
143 (65)
Water used gals per 100 lbs of ice 90 deg air
32.7 (124)
Kilowatts used per 100 lbs of ice 90 deg air
8.8
Btuh
3774
Voltage
220-240V, 50Hz,1phase
No. of wires
3
Min Circuit current
4.9 Amps
Max. Fuse Size
15
Width x Depth x Height
24" x 24" x 39" (60.96 cm x 60.96 cm x 99.06 cm)
Weight
175 lb (79.3800 kg)
Power Output
230 Watts
Air Temp ° F (° C)
Water Temp. °F (°C)
80(27°)
70°(21°)
50°(10°)
90 (32)
133 (60)
170 (77)
80 (27)
161 (73)
173 (79)
191(87)
70 (21)
178 (81)
192 (87)
ICE-O-Matic's optional water filtration system provides protection against unpleasant tastesodors and scale formationConsistent ICE production 24 / 7 by pushing the ICE into the bin rather than waiting for gravity to ever power the scaleAir is drawn in and exhausted from the front - no side clearance requiredBin can be easily removed from the front with four fasteners while the ICE Maker stays in placeDifference between AIR COOLED & WATER COOLEDThe refrigeration system in ice machines have to be cooled during operations because of the heat that is generated during the mechanical process. These are the two types: Air Cooled or Water CooledAir cooled: Good-Uses less water- It is cooled by a fan Good-Better for environmentBad-Has a tendency to heat the room where it is located more than water cooledBad-Little noisier than water cooledGood-Most popularWater cooled: Good-Quieter than air cooledGood-More energy efficientGood-Does not raise room temperatureBad-Cost for water cooled is in some cases higherBad-A lot more water is used which some consider to be a wasteBad-Water bill is higherBad-Water filtration systems have to be changed more frequently because of water usageThese are the good and the bad for both. It's simply the way in which the systems are cooled